Sign In | Join Free | My tjskl.org.cn |
|
Brand Name : HeJin
Model Number : SH-7
Certification : calibration certificate (cost additional)
Place of Origin : China
MOQ : 1 set
Price : Negotiatable
Payment Terms : L/C, T/T
Supply Ability : 10 set /month
Delivery Time : 30 days
Packaging Details : Plywood
Product name : Calibration Device for Spring Impact Hammer SH-7
Standard : IEC 60068-2-75
Measurement range : 0-2J
Operation : Manual
accuracy : 0.01J
IEC60668-2-75 Calibration Device For Spring Hammers Impact Testing Machine
Standard:
IEC 60668-2-75-2014 Environmental testing – Part 2-75: Tests – Test Eh: Hammer tests Annex B;
Application:
This device is intended to verify the impact energy of spring operated impact hammers.
Test sample:
Spring hammer test apparatus
Principle of calibration:
The principle of this calibration procedure is to compare the energy provided by a spring hammer, which is difficult to measure directly, to the energy of a pendulum, calculated from its mass and height of fall.
Parameter:
Model | SH-7 |
Accuracy | 0.01J |
Accuracy | ±0.01J |
Measurement range | 0-2J |
Measurement range | 51mm |
The energy loss of the pendulum | <0.002J |
Trigger distance | >30mm |
Balance weight | 2J Copper weight 1 piece |
![]() |
0.01J Accuracy Calibration Device Impact Testing Machine For Spring Hammer Images |