Sign In | Join Free | My tjskl.org.cn
China HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD logo
HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
Verified Supplier

6 Years

Home > Flammability Testing Equipment >

PLC Control Needle Flame Test Chamber 4mm Coper Block

HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

PLC Control Needle Flame Test Chamber 4mm Coper Block

  • 1
  • 2
  • 3

Brand Name : HeJin

Model Number : NF-2

Certification : calibration certificate (cost additional)

Place of Origin : China

MOQ : 1 set

Price : Negotiatable

Payment Terms : L/C, T/T

Supply Ability : 10 set /month

Delivery Time : 30 days

Packaging Details : plywood

Standard : IEC60695-11-5

Height of the flame : 12±1mm

Temperature measuring distance : 8±1mm

Copper block : Φ4±0.01mm, weight: 0.58±0.01g

inside volume of the chamber : 0.5 m 3

burner : bore of 0,5 mm ± 0,1 mm, outer diameter 0,9 mm

Combustion angle : Tilt 45°( testing )

control mode : PLC control

Contact Now

Flame Test Chamber Needle-Flame Test Apparatus PLC Control 4mm Coper Block

Standard:

IEC 60695-11-5 Fire hazard testing – Part 11 -5: Test flames – Needle-flame test method – Apparatus, confirmatory test arrangement and guidance.

Application:

The Needle-Flame Test Apparatus to simulate the effect of a small flame which may result from fault conditions, in order to assess by a simulation technique the fire hazard.

It is applicable to electrotechnical equipment, its sub-assemblies and components and to solid electrical insulating materials or other combustible materials. Flammability Testing Equipment

Parameter:

ParametersModel NF-2(Touch screen)
Working voltage 220V/50Hz
Control operation mode PLC control, 7 inch color touch screen operation, with infrared remote control
Burner The burner to produce the test flame shall consist of a tube at least 35 mm long with a bore of0.5 mm ± 0.1 mm and an outer diameter not exceeding 0.9 mm.
Gas category Butane or propane gas having a purity of at least 95% ( can use the bottled lighter gas)
Height of the flame 12±1mm adjustable (with flame height gauge)
Temperature increase test time From 100°±5°C to 700°±3°C should be 23.5S±1S
Combustion angle Tilt 45°( testing ) or vertical ( when adjust the height of the flame)
Tray A layer of silk paper (12~30g/m³) is covered on the 10mm thick pine board, with a distance of 200±5mm below the test sample
Timer/sustained combustion 0-9999X0.1S
Temperature measuring distance 8 mm ± 1 mm spacing between the centre of the top of the burner and the remaining portion of the test specimen
Temperature calibration Temperature measuring copper head: Φ4±0.01mm, weight: 0.58±0.01g
Temperature thermocouple: The American original Omega φ0.5 armour nickel-chromium/nickel aluminum wire K-Thermocouple, temperature resistance 1100°
Temperature measuring distance:6±0.5mm
Air volume control The flame height can be adjusted by adjusting the flow meter
Test procedure Automatic control, independent exhaust
Lighting Equip with lighting in the test chamber, with control
Test chamber and dimensions >0.5 cube, inside surface in dark colour, with exhaust fan, size:1100*550*1200mm, weight:130kg

PLC Control Needle Flame Test Chamber 4mm Coper Block


Product Tags:

PLC Flame Test Chamber

      

4mm Coper Block Flame Test Chamber

      

Needle Flame Test Apparatus

      
Quality PLC Control Needle Flame Test Chamber 4mm Coper Block for sale

PLC Control Needle Flame Test Chamber 4mm Coper Block Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
*Subject:
*Message:
Characters Remaining: (0/3000)